Application Note
Per ricevere la documentazione che interessa, cliccare sull'icona nell'ultima colonna.
| Pub Number | Title | Columns highlighted | Done by | Industry | |
|---|---|---|---|---|---|
| 5990-3416EN | Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column | HP-5ms Ultra Inert 30m x 0.25mm x 0.25µm (P/N 19091S-433UI) | CSD | Environmental | |
| 5990-3285EN | Analysis of Volatile Organic Compounds in Water Using Static Headspace-GC/MS | DB-624, 20m x 0.18mm x 1.0µm (P/N 121-1324) | CASU | Environmental | |
| 5989-9727EN | Analysis of OCPs in Marine Biota Extract Using the Agilent 7000A Triple Quad GC/MS | HP-5ms Ultra Inert 30m x 0.25mm x 0.25µm (P/N 19091S-433UI) | CASU | Environmental | |
| 5990-3253EN | Fast and Accurate EPA 8270 Quantitation Using Deconvolution | DB-5ms 30m x 0.25mm x 0.25µm (P/N 122-5532) | CASU | Environmental | |
| 5990-3366EN | Determination of Nitro-Polycyclic Aromatic Hydrocarbons in Air Particulates Using GC-Triple Quadrupole-MS | DB-5ms Ultra Inert 15m x 0.25mm x 0.25µm (P/N 122-5512UI) | CASU | Environmental | |
| 5990-3473EN | Analysis of Organochlorine pesticides in Drinking Water by Agilent 7820 Gas Chromatograph/Micro-Electron Capture Detector | DB-1701 30 m x 0.32 mm x 0.25 µm (P/N 123-0732) | CASU | Environmental | |
| 5990-3737EN | Chlorinated Solvents and Disinfection By-Product Analysis Using an Agilent J&W HP-1ms Ultra Inert and DB-1301 Capillary GC Columns | HP-1ms Ultra Inert 30 m x 0.25 mm x 1.0 µm (P/N19091S-733UI) DB-1301 30 m x 0.25 mm x 1.0 µm (P/N 122-1333) |
CSD | Environmental | |
| 5990-3282EN | Trace-Level Analysis of Melamine in Milk Products on Agilent 7890A/5975C GC/MSD Using a New Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges | DB-5ms Ultra Inert 30m x 0.25mm x 0.25µm (P/N 122-5532UI) | CSD | Food / Flavors / Fragrances | |
| 5990-3700EN | Lavender Oil Characterization Using Agilent J&W DB-1ms Ultra Inert Capillary GC Columns | DB-1ms Ultra Inert 30 m x 0.25 mm x 0.25 µm (P/N 122-0132UI) | CSD | Food / Flavors / Fragrances | |
| 5990-3640EN | Toxicology Screening of Whole Bolld Extracts Using GC Triple-Quadrupole-MS | DB-5ms Ultra Inert 15 m x 0.25 mm x 0.25 µm (P/N 122-5512UI) | CASU | Forensic | |
| 5990-3237EN | Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector | HP-1 10m x 0.53mm x 0.88µm (P/N 19095Z-021) DB-HT-SimDis 5m x 0.53mm x 0.15µm (145-1001) |
CASU | HPI | |
| 5990-3548EN | Analysis of Trace Hydrocarbon Impurities in Benzene by Agilent 7820A Gas Chromatograph | HP-INNOWax 60 m x 0.32 µm x 0.5 µm (P/N 19091N-216) | CASU | HPI | |
| 5990-3781EN | Automated Standard and Sample Preparation for Multiple Gas Chromatographic Analyses of Biodiesel | HP-INNOWax 30 m x 0.32 mm x 0.25 µm, 4" cage (19091N-113V) Biodiesel ASTM D6584 Free/Total Glycerin 15 m x 0.32 mm x 0.1 µm film (123-BD11) 2 m x 0.53 mm retention gap (160-2865-5) |
CASU | HPI | |
| 5990-3428EN | Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds | HP-5ms 30m x 0.25mm x 0.25µm (P/N 19091S-433) Cyclodex-B 30m x 0.25mm x 0.25µm, LTM (112-2532LTM) |
CASU | LTM | |
| 5990-3576EN | Analysis of Suspected Flavor and Fragrance Allergens in Perfumes using Two-dimensional GC with Independent Column Temperature Control Using an LTM Oven Module | HP-5MS 30 m x 0.25 mm x 0.25 µm (P/N 19091S-433) DB-17ms 30 m x 0.25 mm id x 0.25 µm, LTM (P/N 122-4732LTM) |
CASU | LTM | |
| 5990-3778EN | Automated Preparation of Simulated Distillation Samples for ASTM Methods D2887, D7213, D7398 and D6352 Using a Dual Tower 7693A and Tray |
|
CASU | LTM | |
| 5990-3451EN | Fast Analysis of Polynuclear Aromatic Hydrocarbons Using Agilent Low Thermal Mass (LTM) GC/MS and Capillary flow Technology Quick Swap for Backflush | DB-5ms 30 m x 0.25 mm x 0.25 µm (P/N 122-5532) DB-5ms 20 m x 0.18 mm x 0.18 µm, LTM (P/N 121-5522LTM) |
CASU | LTM | |
| 5990-3868EN | Boiling Point Range of Fatty Acid Methyl Esters Using the 7890A Gas Chromatograph, Low Thermal Mass (LTM) System, and 7693A Tower and Tray | DB-HT SimDis 5M x 0.53 mm x 0.15 µm, LTM DB-HT SimDis 5M x 0.53 mm x 0.15 µm (P/N 145-1001) |
CASU | LTM | |
| 5990-3367EN | Improving GC/MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing | HP-5MS Ultra Inert 15.0 m x 0.25mm x 0.25 µm (P/N 19091S-431UI) 0.80 m x 0.15 mm uncoated deactivated fused silica (order P/N 160-2625-1) |
CASU | General |